Device Features:
★ This equipment is suitable for hot pressing molding of large-diameter aspheric lenses.
★ This equipment can meet the production requirements of one mold and one cavity or one mold and multiple cavities.
★ The operating interface of this equipment is equipped with a capacitive screen and proprietary software with reserved customization and upgrade space. It has temperature abnormality alarm, cooling water, nitrogen, and compressed air abnormality alarms, and molding NG alarms. All alarm information is indicated by sound and light alarms, and recorded and stored. Electricity consumption, cooling water, and nitrogen are all equipped with flow monitoring systems and devices.
NOProject distinction content Detailed specifications
1Basic parameters power source Power supply: three-phase 200VAC/40KVA, three-phase 380VAC/40KVA (optional) starting power: 37KW: operating power: 11~15KW
Compressed air: 0.55MPa±5%, 55L/min:
Cooling water: 03MPa, 14~25L/min, 20±1℃
Nitrogen: 0.3MPa±5% (purity 99.999%), 14~24 liters/min, oxygen content ≤2ppm
Diameter ф16~ф90mm: Square: 85mmx85mm
The allowable height range of the total height of the upper and lower mold cores (including the preform): 22mm~68mm Scope of application: one cavity for one mold, multiple cavities for one mold
Mold specification Maximum working temperature700°, 750°C (optional) heating time is less than 15Min
Dimensions 2032(L)x1584(W)x2090(H); Weight about: 1200kg
2Mold transfer transfer Mold transfer by air cylinder and high-precision electric cylinder
3Environmental requirements cleanliness Below class 10000 (recommend below class 1000, or place 100 class FFU on the operating platform to ensure local cleanliness)
environment humidity 30-60%, but no condensation
ambient temperature 22℃±3℃, but no condensation
4Vapor Specifications Upper vapor chamber size 120mm(L)x100mm(W)x10(H)
Lower vapor chamber size 120mm(L)x108mm(W)*10(H)
Vapor Material Alloy plate, ceramic plate (optional)